Electronic Detonator for the Oil Industry
It is intended for perforation applications in conventional and unconventional wells. It is highly versatile as it can be used from 2 ¾” lateral port tandems or any modular gun.
VENG’s EDS allows for the individual selection of the detonator to be used, with the capability to initiate ETACORD 80 RDX detonating cord.
Inicio // Services // Industrial Developments // Electronic Detonator – Oil & Gas – Mining
It is intended for perforation applications in conventional and unconventional wells. It is highly versatile as it can be used from 2 ¾” lateral port tandems or any modular gun.
VENG’s EDS allows for the individual selection of the detonator to be used, with the capability to initiate ETACORD 80 RDX detonating cord.
EDS VENG is based on API-RP67 standard—
- A control unit to operate from 1 up to 16 devices that allows the operator to control each device/detonator from a safe distance.
- A communication medium between the control unit and the detonator.
- Detonators with the ability to be connected in Daisy chain and controlled remotely and individually.
- A system verification/testing unit without detonation capability.
ELECTRICAL FEATURES
Tests
RADIATED SUSCEPTIBILITY (RF-SAFE)
Tested at 200V/m in the range of 100MHz to 6GHz. Safe and functional.
ESD
Tested under HBM IEC model +/-25KV; 150pF; 330 Ohm.Safe and functional.
DIRECT CURRENT
Tested at 220V AC – 50Hz. Safe.
MECHANICAL FEATURES
Tests
TEMPERATURE
150°C during 1 hour. Safe and functional.
TENSILE STRENGTH
31N of traction between the detonator body and the cables.
FLUID INERTIZATION
Tested 2min@2bar. Chemical and electronic fluid sensitive.
OPERATIVE FEATURES
Design
POWER SUPPLY VOLTAGE
28V+/-4V DC exclusive to VENG Firing Panel.
PRIMARY CHARGE
150mg PbN6
SECONDARY CHARGE
600mg RDX
PLASTIC CHASSIS
50mm in length; with integrated holes for detonating cord passage.
STORAGE
4 year under storage conditions of -40°C to +70°C and RH ≤65% with frequent ventilation.